Description
The following functions are available when having and carrying the Intelligent Key.
Remote control entry function and panic alarm function are available when operating the remote buttons.
Component Function Check
NOTE: The Signal Tech II Tool (J-50190) can be used to perform the following functions. Refer to the Signal Tech II User Guide for additional information.
1. CHECK FUNCTION
With CONSULT
Check remote keyless entry receiver RKE OPE COUN1 in Data Monitor mode with CONSULT.
Diagnosis Procedure
NOTE: The Signal Tech II Tool (J-50190) can be used to perform the following functions. Refer to the Signal Tech II User Guide for additional information.
1. CHECK INTELLIGENT KEY BATTERY
Check by connecting a resistance (approximately 300Ω) so that the current value becomes about 10 mA.
Standard : Approx. 2. 5 - 3. 0V
2. CHECK KEYFOB FUNCTION
Check keyfob function using Signal Tech II Tool J-50190 or Remote Keyless Entry Tester J-43241 (shown).
Hazard switch
Exploded View
Hazard switch
Cluster lid D
Removal and Installation
REMOVAL
Remove cluster lid D. Refer to IP-18, "Removal and Installation".
Disconnect the harness connector from the hazard switch and
remove.
INSTALLATION
Installation is in the reverse order of removal. ...
Front wiper motor hi circuit
Component Function Check
1. CHECK FRONT WIPER HI OPERATION
IPDM E/R AUTO ACTIVE TEST
Start IPDM E/R auto active test. Refer to PCS-11, "Diagnosis
Description".
Check that the front wiper operates at the HI operation.
CONSULT ACTIVE TEST
Select "FRONT WIPER" of IPDM E/R active test ...
Interior room lamp
Wiring Diagram
...