To reprogram a HomeLink Universal Transceiver button, complete the following: 1. Press and hold the desired HomeLink button.
DO NOT release the button.
2. The indicator light will begin to flash after 20 seconds. Without releasing the HomeLink button, proceed with "Programming HomeLink" - Step 1.
For questions or comments, contact HomeLink at: www.homelink.com or 1-800-355-3515 (except Mexico).
The HomeLink Universal Transceiver button has now been reprogrammed. The new device can be activated by pushing the HomeLink button that was just programmed. This procedure will not affect any other programmed HomeLink buttons.
Interior room lamp control system
System Diagram
System Description
OUTLINE
Interior room lamps* are controlled by interior room lamp timer
control function of BCM.
*:Front room/map lamp assembly, foot lamps and
rear personal lamps (when front room/map lamp assembly switch is in DOOR
position).
Trunk room lamp is ...
Key slot illumination
Description
Blinks when Intelligent Key insertion is required.
Component Function Check
1.CHECK FUNCTION
With CONSULT
Check key slot illumination ("KEY SLOT ILLUMI") Active
Test mode.
Diagnosis Procedure
Regarding Wiring Diagram information, refer to SEC-147,
"Wiring Diagram" or SEC-128, ...
Interior room lamp control circuit
Description
Controls each interior room lamp (ground side) by PWM signal.
NOTE: PWM signal control period is
approximately 250 Hz (in the gradual brightening/dimming).
Component Function Check
CAUTION: Before performing the diagnosis,
check that the following is normal.
Battery saver ou ...