Description
Fuel gauge needle will not move from a certain position.
Diagnosis Procedure
1.CHECK COMBINATION METER INPUT SIGNAL
Select "METER/M&A" on CONSULT.
Using "FUEL METER" of "DATA MONITOR", compare the monitor value with the fuel gauge reading on the combination meter. Refer to MWI-40, "Component Function Check".
2.CHECK FUEL LEVEL SENSOR SIGNAL CIRCUIT
Check the fuel level sensor signal circuit. Refer to MWI-40, "Diagnosis Procedure".
3.CHECK FUEL LEVEL SENSOR UNIT AND FUEL PUMP (FUEL LEVEL SENSOR)
Perform a unit check for the fuel level sensor unit and fuel pump (fuel level sensor). Refer to MWI-41, "Component Inspection".
4.CHECK FLOAT INTERFERENCE
Check that the float arm does not interfere or bind with any of the components in the fuel tank.
Front door speaker
Removal and Installation
REMOVAL
Remove the front door finisher. Refer to INT-18, "Removal and
Installation".
Remove the front door speaker screws (A).
Disconnect the harness connector from the front door speaker
(1) and remove.
Remove the front door speaker spacer screws (B) and ...
Subwoofer AMP
Removal and Installation
Subwoofer amp. and bracket
Subwoofer amp. bracket screws
REMOVAL
Disconnect the battery negative terminal. Refer to PG-67, "Removal
and Installation (Battery)".
Remove the parcel shelf finisher. Refer to INT-28, "Removal and
Installation". NOTE: The ...
U1207 AV control unit
DTC Logic
Diagnosis Procedure
1.PERFORM THE SELF-DIAGNOSIS
Delete the "self-diagnosis" results of "MULTI AV". Turn ignition
switch OFF.
Turn ignition switch ON. Perform the self-diagnosis again.
Check that the DTC is detected again.
U1216 AV CONTROL UNIT
DTC Logic
U1217 AV ...